Welcome: China Tianjin Recare Co., Ltd.

Malaria Test

  • malaria kits rapid supplier prueba one step accurate diagnostic
  • malaria kits rapid supplier prueba one step accurate diagnostic
  • malaria kits rapid supplier prueba one step accurate diagnostic
  • malaria kits rapid supplier prueba one step accurate diagnostic
  • malaria kits rapid supplier prueba one step accurate diagnostic
malaria kits rapid supplier prueba one step accurate diagnosticmalaria kits rapid supplier prueba one step accurate diagnosticmalaria kits rapid supplier prueba one step accurate diagnosticmalaria kits rapid supplier prueba one step accurate diagnosticmalaria kits rapid supplier prueba one step accurate diagnostic

malaria kits rapid supplier prueba one step accurate diagnostic

  • Product description: Recare rapid diagnostic test for malaria kits High Standard Diagnostic sensitivity is 99%, Accuracy/effectiveness 99%.
  • INQUIRY

Recare rapid diagnostic test for malaria kits High Standard Diagnostic sensitivity is 99%, Accuracy/effectiveness 99%.

malaria kits rapid supplier prueba one step accurate diagnostic

Our mission is to produce and sell the highest quality rapid tests for humans.
Malaria Pf/Pv Antigen Rapid Test is a rapid, qualitative test for the detection of Plasmodium falciparum and/or Plasmodium vivax, (Plasmodium orale and Plasmodium malariae) antigen in whole blood. The test uses antibodies that are specific for the histidine-rich protein 2 antigen (HRP-2) of Malaria P.f. and Plasmodium aldolase for the detection of all malaria Plasmodium species.

PRODUCT DESCRIPTION

malaria kits rapid supplier prueba one step accurate diagnostic

Function  For the qualitative detection of Malaria Pf/Pv antigen in whole blood
Formats  cassette, strip
Specifications  cassette(3mm, 4mm)

or according to the customers’ requirements

Specimens  whole blood
Sensitivity  10mIU/ml, 25mIU/ml
Specificity  99%
Reaction Time 15 minutes
Shelf Life  24 months at room temperature 4- 30 degrees
Packing Details   Cassette

40pcs/bag, 50bags/carton.  500,000pcs/20’ft container

40pcs/box, 50boxes/carton, 550,000pcs/20’ft container

1pcs/box, 500boxes/carton, 120,000pcs/20’ft container
Strip

100pcs/bag, 100bags/carton .1,300,000pcs/20’ft container

100pcs/box, 50boxes/carton, 1,700,000pcs/20’ft container

50pcs/box, 100boxes/carton, 1,600,000pcs/20’ft container

1pcs/box, 500boxes/carton, 120,000pcs/20’ft container

Others  The kits can be made according to the customers’ artwork or design

 

ASSAY PROCEDURE

  1. Allow all reagents and samples to achieve room temperature.
  2. Remove the cassette from the foil pouch and place it on a clean flat dry surface.
  3. Add 5 ul of whole blood to the sample well. Now add 3-4 drops of buffer (~100 ul). Start the timer.
  4. Interpret the test result in 20 minutes. Discard the cassette after 20 min. to avoid incorrect results.

REAGENTS AND MATERIALS PROVIDED

1 One pouch sealed with desiccant
2 Blood diluent buffer in a dropper bottle
3 One package insert

MATERIALS REQUIRED BUT NOT PROVIDED

  1. Clock or Timer
  2. Lancing device for whole blood test

SAMPLE COLLECTION AND PREPARATION

Whole Blood:
Drops of whole blood can be obtained either from finger or vein puncture. Whole blood should be stored not more than 3 days in refrigerator at 2-4 degrees if not used immediately.

PRODUCT INSTRUCTION DISPLAY

malaria kits rapid supplier prueba one step accurate diagnostic

China Recare rapid diagnostic test for malaria kits High Standard Diagnostic sensitivity is 99%, Accuracy/effectiveness 99%.China Recare rapid diagnostic test for malaria kits High Standard Diagnostic sensitivity is 99%, Accuracy/effectiveness 99%.

China Recare rapid diagnostic test for malaria kits High Standard Diagnostic sensitivity is 99%, Accuracy/effectiveness 99%.

Negative results:

Only the control red band will appear.

Positive results:

Pf positive: Two red bands will appear. One in control zone and other in Pf (T2) zone.
Pv positive: Two red bands will appear. One in control zone and other in Pv (T1) zone.
Mixed positive: Three red bands will show up in Control, Pf (T2), & Pv (T1) zone.

Invalid results:

If no band shows up in the control zone, the test result is invalid even though red bands show up in Pf (T2) & or Pv (T1) zones. If no red bands show up in the test zone, the test is also invalid.

malaria kits rapid supplier prueba one step accurate diagnostic

OUR FACTORY AND WORKSHOP

China Tianjin Recare Co., Ltd. is a pioneer in the rapid test manufacturing industry and distribution in China,has been in this line more than 15 years. We owned more than 100 workers, the capacity is more than 1 million pieces of test per month. Our rapid test has been sold in more than 160 countries and places. Rapid tests supplied by Recare are highly regarded for high accuracy and reliability in the commercial markets and non-commercial markets.We are also the supplier of UN.

China Recare rapid diagnostic test for malaria kits High Standard Diagnostic sensitivity is 99%, Accuracy/effectiveness 99%.

OUR ADVANTAGES

  1. Best service: quality control, convenient custom clearance, door to door shipping service
  2. Faster email response on every inquiry and high quality competitive price
  3. Small quantity orders are acceptable
  4. Rich experience to work with famous company and brands
  5. OEM packaging : custom foil pouch,custom small box,custom medium box,custom carton
  6. Supply free samples
  7. Timely sample and mass production delivery date

PRODUCTION PROCESS

China Recare rapid diagnostic test for malaria kits High Standard Diagnostic sensitivity is 99%, Accuracy/effectiveness 99%.

OUR CERTIFICATES

China Recare rapid diagnostic test for malaria kits High Standard Diagnostic sensitivity is 99%, Accuracy/effectiveness 99%.
CE, ISO CERTIFICATE…

OUR EXHIBITIONS

China Recare rapid diagnostic test for malaria kits High Standard Diagnostic sensitivity is 99%, Accuracy/effectiveness 99%.

 

OUR MARKET

Our Rapid Tests have been sold to more than 160 countries in the world,such as European countries,Africa,Middle East,South America.
China Recare rapid diagnostic test for malaria kits High Standard Diagnostic sensitivity is 99%, Accuracy/effectiveness 99%.
hepatitis a antibody test rapid distributor prueba rapida HAV IgG / IgM

QUESTIONS AND ANSWERS

Q1: Are you a trade company or a manufacturer?

A: We are an ISO&CE approved manufacturer specialized in rapid test for over 20 exporting years.OEM & ODM service are available.

Q2: What is your MOQ?

A: 5000 Pieces

Q3: What is your delivery date?

A: The delivery date is 35-40 days after packing designs approved, and receipt of deposit.

Q4: What is your payment terms?

A: Payment terms: 30% deposit in advance and 70% balance before shipment or upon the receipt of B/L copy.

Q5: Can you send samples?

A: Yes,SAMPLES can be sent for your evaluation.customer pay the freight charges.

Our export experience

Our factory is a scientific and technological factory, which designs, manufactures and sales of In-vitro-Medical diagnosis devices. It is in possession of modern workshop and advanced facilities.
For quality,we have CE,ISO13485.
The main products include HCG series (including Pregnancy test strip, Pregnancy test cassette, Pregnancy test midstream), LH test strip, Chemical Reagent strips for urinalysis and other products such as HIV, HP-ab, Malaria,FOB,HAV,Hepatitis B, Hepatitis C, syphilis and other toxin test strip and cassette. The certificates and licenses of products are all complete. Product attained many design patents, including BCT, LADYLUCK and more other registered brand. Products especially LADYLUCK series deeply gained customers’ good appraisal. Production amount have an ascending trend year after year. Quality and performance are steady.

Our products were sold in national also farforth to all over the world. Its characters and performances state superior among products alike, never have any quality question.

 

China Recare rapid diagnostic test for malaria kits High Standard Diagnostic sensitivity is 99%, Accuracy/effectiveness 99%.